INSTRUMENT AND CONTROL INSPECTION SERVICES

SMALL BORE TUBING ASSEMBLIES

​​We follow the recommended practice for conducting the inspection of Small Bore Tubing (SBT) assemblies. By doing so we aim to ensure that formal guidance and controls are utilised to maintain the safety and integrity of all SBT and the systems in which they are installed. This will help to minimise the risk to personnel and plant resulting from a loss of integrity of SBT assemblies as far as reasonably practicable.

Inspections and their frequency are essential to mitigate against the loss of containment, with the potential for a major release being attributed to:

  • Under or over tightened fittings (leak potential)

  • Crevice corrosion under clamp / metal to metal contact

  • Inadequate supports for tubing

  • Pitting and physical damage to tubing

  • Poor installation practice / competence

  • Lack of effective inspection and maintenance

  • Inadequate design of SBT assemblies

WHO WE ARE
image.png
rs=w_1200,cg_true.webp

HAZARDOUS AREA INSTALLATION, REPAIR AND INSPECTIONS

Maintain Control can provide Hazardous Area Instrumentation Installation, repair and inspection services with support services ranging from Area Classification, Ex / ATEX Installation, Ex (ATEX) Inspections to Ex / ATEX Management & Policy Services.

​

We understand that many companies do not have the necessary understanding or in-house expertise to ensure hazardous area electrical installation and inspection compliance in accordance with the ATEX directives (commonly referred to as ATEX 95 & ATEX 137) and The Dangerous Substances and Explosive Atmospheres Regulations 2015 (DSEAR) all of which address safety where there is a danger from potentially explosive atmospheres.

​

Our highly trained and experienced CompEx certified engineers, technicians and electricians have specialist expertise in ‘Hazardous Area’ electrical installation, inspection, testing and maintenance of installations employing types of protection Ex’i’, Ex’d’, Ex’e’, Ex’p’, Ex’m’, Ex’n’, Ex’o’, Ex’s’, Ex’op’, Ex’q’ and Ex’t’ as defined by the IEC 60079 set of Standards.

​

We offer our customers well managed hazardous area electrical inspection programs which ensure that equipment installed in potentially explosive atmospheres is compliant to the relevant standards, installed as per the manufacturers certification recommendations, correctly specified and has no defects which may render the equipment unsafe for continued use.